FIA/Research
Archive
Browse +
The architecturesMeeting chronologyAbout the archive
Future Internet ArchitectureHistorical collection · 2010—2015

Research archive

Bitcoin mining connection problems: a layer-by-layer checklist

Separate DNS, TCP, TLS and worker authorisation failures before changing an ASIC or moving a whole mining setup.

A responding ping is not a successful mining connection. A miner still needs to reach the right service, use a compatible protocol and submit work that the pool accepts. Keeping those stages separate makes a failed connection much easier to diagnose.

This practical networking note is a new addition to the site, not a recovered FIA meeting paper. Use it with equipment and network services you own or are authorised to administer.

Write down the failure before changing anything

Record the time, miner model, firmware version and exact error from the miner log. Copy the pool hostname, port and transport setting from the operator’s current connection instructions. Keep passwords, API tokens and public payout addresses out of screenshots you plan to share.

Distinguish a worker that never appears from one that repeatedly disconnects. A connection that remains open while shares are rejected needs a different investigation from a hostname that cannot be resolved. Avoid rebooting the router, changing firmware and switching pools together: that removes the evidence needed to identify the cause.

1. Confirm local access and name resolution

Check the Ethernet link and the miner’s IP address, gateway and DNS settings. A computer on the same network can help inspect the configured hostname, but a successful lookup on that computer does not prove the miner is using the same resolver. Check the miner’s settings as well.

If the operator uses a hostname, retain it rather than permanently substituting an IP address. The hostname may select a regional service, and encrypted connections may require it for certificate verification. DNS answers can change without the operator changing the published connection address.

2. Test the documented service port

Ping uses ICMP; the mining service may use TCP on another port. ICMP can be blocked while the service works, or permitted while the service port is inaccessible. Test only the documented hostname and port, not a range of guessed ports.

On Windows, PowerShell’s Test-NetConnection command can test a known TCP endpoint. Replace both placeholders with the operator’s published values before running this example:

Test-NetConnection -ComputerName POOL_HOSTNAME -Port DOCUMENTED_PORT

A successful TCP connection proves that a transport connection could be established from that computer at that moment. It does not prove that a miner logged in, received a job or submitted an accepted share. A timeout can reflect a firewall, routing problem or unavailable service; it does not, by itself, identify which one.

3. Match the protocol and encryption settings

Use the transport and protocol version documented for that endpoint and supported by the miner’s firmware. Do not assume that a service supports Stratum V2 because another pool does. Likewise, an encrypted endpoint and a plain TCP endpoint are not interchangeable.

For a TLS-enabled service, an incorrect device clock or a certificate validation error can interrupt the connection after TCP succeeds. Correct the clock and check the documented hostname. Do not disable certificate verification to turn a failed test into an apparent success.

4. Check worker authorisation and accepted work

If the log reports an authorisation failure, compare the account and worker-name format with the operator’s instructions. Different services use different naming conventions. An accessible website and a valid website login do not establish that the worker configuration is correct.

Once the worker is connected, note accepted, stale and invalid shares over a defined interval. Preserve the exact rejection reason. Stale work may indicate late submissions, while invalid work may point to calculation, configuration or protocol issues. A single rejection is not enough to diagnose unstable hardware or a bad network.

Make the next test small enough to explain

Change one variable on one miner, then repeat the observation for the same length of time. For intermittent faults, include the time of each disconnect and whether other devices lost connectivity. Use a wired comparison where practical, and avoid changing production firewall rules without a rollback plan.

When the connection is stable, move on to the mining pool test log to separate network behaviour from earnings and payout timing. The original FIA availability and evaluation meeting record provides historical context for the wider measurement questions, rather than mining configuration advice.

Command reference: Microsoft’s Test-NetConnection documentation.